Configure DS0 ports for GR-57 interface
|
Host DS0 ports provide a GR-57 switch interface for DS0 services. Remote DS0
ports provide a subscriber interface for DS0 services. You configure the host
ports for the type of service connected to the switch, and the remote ports for
the type of DS0 service delivered.
|
|
Configuring host and remote DS0 ports services
|
Ports on host and remote DS0 equipment can be configured for many DS0 switched
services:
|
-
POTS service for ports on HPOTS-24 and HU2W-24 host cards and RPOTS-24 and
RU2W-24 remote cards.
-
Coin service on the first four ports of the HU2W-24 host card and the first
four ports of the RU2W-24 remote card. Set the GSFN parameter to 2COIN.
-
UVG service on DS0 ports on the HPOTS-24 and HU2W-24 host cards and RPOTS-24
and RU2W-24 remote cards. Set the GSFN parameter to a UVG service type.
-
EBS service on the HEBS-12 host card and REBS-12 remote card. Port parameters
on an HEBS-12 and REBS-12 cards are set for EBS service.
|
|
|
Procedure to set DS0 port parameters
 |
|
The DS0 port parameter illustrations in step 5 show parameter values for POTS
service. Choose different values to configure the port for other DS0 services.
|
|
|
|
Step
|
Action
|
|
1.
|
On the Navigation Tree,
click a shelf containing DS0 ports.
|
|
2.
|
On the Filter list,
click Facility, then click DS0 Facility to show all DS0 ports from the selected
shelf in the Work Area.
|
|
3.
|
On the Provisioning
page, click the first DS0 port to configure then press shift and click the last
DS0 port to select a range of ports to configure.
|
|
4.
|
On the provisioning page set the following DS0 parameters:
- In the Primary Service State list, click Out of Service to place the port
out of service.
- In the General Signaling Function list, click a signal type.
- In the Receive Transmission Level Point list, click a decibel value.
- In the Transmit Transmission Level Point list, click a decibel value.
- In the Impedance list, click an impedance of 600 or 900 ohms.

|
|
5.
|
On the toolbar, click
Apply, then click OK to save the DS0 port configuration.
|
|
6.
|
On the Provisioning page, select the same range of ports to configure as
selected in step 3.
|
|
7.
|
In the Primary Service
State list, click In Service to place the port back in service.
|
|
8.
|
On the toolbar, click
Apply, then click OK to put the DS0 port back into service.
|
|
9.
|
If you have just set DS0 host port parameters, repeat steps 1 through 8 for the
corresponding remote ports.
|
|
|
|
|
|
|
 |
 |
|
Copyright © Calix 2001-2004. All Rights Reserved
Powered by OutStart Evolution® 2.2.2.7-2
|